Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 49.64µH
Inductance - Connected In Series 198.6µH
Tolerance ±20%
Current Rating - Parallel 1.15A
Current Rating - Series 573mA
Current Saturation - Parallel 1.41A
Current Saturation - Series 710mA
DC Resistance (DCR) - Parallel 216mOhm
DC Resistance (DCR) - Series 865mOhm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.299" L x 0.299" W (7.60mm x 7.60mm)
Height 0.175" (4.45mm)
DRQ73-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 137.6µH Inductance - Connected in Series 34.41µH Inductance - Connected in Parallel 166mOhm DC Resistance (DCR) - Parallel 1.31A Nonstandard, DRQ
View
DRQ74-220-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 86.92µH Inductance - Connected in Series 21.73µH Inductance - Connected in Parallel 92.5mOhm DC Resistance (DCR) - Parallel 1.75A Nonstandard, DRQ
View
DRQ73-3R3-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 14.16µH Inductance - Connected in Series 3.54µH Inductance - Connected in Parallel 25.9mOhm DC Resistance (DCR) - Parallel 3.31A Nonstandard, DRQ
View
DRQ125-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 21.1µH Inductance - Connected in Series 5.274µH Inductance - Connected in Parallel 10.5mOhm DC Resistance (DCR) - Parallel 7.18A Nonstandard, DRQ
View
DRQ127-220-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 91.72µH Inductance - Connected in Series 22.93µH Inductance - Connected in Parallel 39.1mOhm DC Resistance (DCR) - Parallel 4A Nonstandard, DRQ
View
DRQ73-471-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 1.863mH Inductance - Connected in Series 465.8µH Inductance - Connected in Parallel 2.36Ohm DC Resistance (DCR) - Parallel 350mA Nonstandard, DRQ
View
DRQ127-2R2-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 8.108µH Inductance - Connected in Series 2.027µH Inductance - Connected in Parallel 3.73mOhm DC Resistance (DCR) - Parallel 12.5A Nonstandard, DRQ
View
DRQ74-102-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 4.036mH Inductance - Connected in Series 1.009mH Inductance - Connected in Parallel 3.89Ohm DC Resistance (DCR) - Parallel 270mA Nonstandard, DRQ
View
DRQ73-6R8-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 25.92µH Inductance - Connected in Series 6.48µH Inductance - Connected in Parallel 43.5mOhm DC Resistance (DCR) - Parallel 2.55A Nonstandard, DRQ
View
DRQ125-221-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 867.2µH Inductance - Connected in Series 216.8µH Inductance - Connected in Parallel 384mOhm DC Resistance (DCR) - Parallel 1.19A Nonstandard, DRQ
View
DRQ127-3R3-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 11.32µH Inductance - Connected in Series 2.831µH Inductance - Connected in Parallel 5.67mOhm DC Resistance (DCR) - Parallel 10.4A Nonstandard, DRQ
View
DRQ74-100-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 39.53µH Inductance - Connected in Series 9.882µH Inductance - Connected in Parallel 48.9mOhm DC Resistance (DCR) - Parallel 2.41A Nonstandard, DRQ
View