Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 33.74µH
Inductance - Connected In Series 135µH
Tolerance ±20%
Current Rating - Parallel 3.28A
Current Rating - Series 1.64A
Current Saturation - Parallel 3.84A
Current Saturation - Series 1.92A
DC Resistance (DCR) - Parallel 50.5mOhm
DC Resistance (DCR) - Series 203mOhm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.492" L x 0.492" W (12.50mm x 12.50mm)
Height 0.236" (6.00mm)
DRQ73-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 194.5µH Inductance - Connected in Series 48.62µH Inductance - Connected in Parallel 241mOhm DC Resistance (DCR) - Parallel 1.08A Nonstandard, DRQ
View
DRQ127-150-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 56.36µH Inductance - Connected in Series 14.09µH Inductance - Connected in Parallel 24.7mOhm DC Resistance (DCR) - Parallel 5.03A Nonstandard, DRQ
View
DRQ127-221-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 886µH Inductance - Connected in Series 221.5µH Inductance - Connected in Parallel 376mOhm DC Resistance (DCR) - Parallel 1.29A Nonstandard, DRQ
View
DRQ125-681-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 2.719mH Inductance - Connected in Series 679.8µH Inductance - Connected in Parallel 1.1Ohm DC Resistance (DCR) - Parallel 700mA Nonstandard, DRQ
View
DRQ73-150-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 60.04µH Inductance - Connected in Series 15.01µH Inductance - Connected in Parallel 84.4mOhm DC Resistance (DCR) - Parallel 1.83A Nonstandard, DRQ
View
DRQ127-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 135.7µH Inductance - Connected in Series 33.92µH Inductance - Connected in Parallel 60mOhm DC Resistance (DCR) - Parallel 3.23A Nonstandard, DRQ
View
DRQ74-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 132µH Inductance - Connected in Series 33.01µH Inductance - Connected in Parallel 143mOhm DC Resistance (DCR) - Parallel 1.41A Nonstandard, DRQ
View
DRQ127-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 397.2µH Inductance - Connected in Series 99.31µH Inductance - Connected in Parallel 163mOhm DC Resistance (DCR) - Parallel 1.96A Nonstandard, DRQ
View
DRQ127-680-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 265.9µH Inductance - Connected in Series 66.48µH Inductance - Connected in Parallel 105mOhm DC Resistance (DCR) - Parallel 2.44A Nonstandard, DRQ
View
DRQ73-3R3-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 14.16µH Inductance - Connected in Series 3.54µH Inductance - Connected in Parallel 25.9mOhm DC Resistance (DCR) - Parallel 3.31A Nonstandard, DRQ
View
DRQ73-2R2-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 8.28µH Inductance - Connected in Series 2.07µH Inductance - Connected in Parallel 16.7mOhm DC Resistance (DCR) - Parallel 4.11A Nonstandard, DRQ
View
DRQ127-821-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 3.272mH Inductance - Connected in Series 818.1µH Inductance - Connected in Parallel 1.47Ohm DC Resistance (DCR) - Parallel 650mA Nonstandard, DRQ
View