Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 33.74µH
Inductance - Connected In Series 135µH
Tolerance ±20%
Current Rating - Parallel 3.28A
Current Rating - Series 1.64A
Current Saturation - Parallel 3.84A
Current Saturation - Series 1.92A
DC Resistance (DCR) - Parallel 50.5mOhm
DC Resistance (DCR) - Series 203mOhm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.492" L x 0.492" W (12.50mm x 12.50mm)
Height 0.236" (6.00mm)
DRQ125-6R8-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 26.35µH Inductance - Connected in Series 6.588µH Inductance - Connected in Parallel 12.3mOhm DC Resistance (DCR) - Parallel 6.64A Nonstandard, DRQ
View
DRQ74-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 198.6µH Inductance - Connected in Series 49.64µH Inductance - Connected in Parallel 216mOhm DC Resistance (DCR) - Parallel 1.15A Nonstandard, DRQ
View
DRQ74-150-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 64.36µH Inductance - Connected in Series 16.09µH Inductance - Connected in Parallel 63.7mOhm DC Resistance (DCR) - Parallel 2.11A Nonstandard, DRQ
View
DRQ125-100-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 38.62µH Inductance - Connected in Series 9.654µH Inductance - Connected in Parallel 18.9mOhm DC Resistance (DCR) - Parallel 5.35A Nonstandard, DRQ
View
DRQ127-6R8-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 29.55µH Inductance - Connected in Series 7.387µH Inductance - Connected in Parallel 11.6mOhm DC Resistance (DCR) - Parallel 7.34A Nonstandard, DRQ
View
DRQ74-102-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 4.036mH Inductance - Connected in Series 1.009mH Inductance - Connected in Parallel 3.89Ohm DC Resistance (DCR) - Parallel 270mA Nonstandard, DRQ
View
DRQ125-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 135µH Inductance - Connected in Series 33.74µH Inductance - Connected in Parallel 50.5mOhm DC Resistance (DCR) - Parallel 3.28A Nonstandard, DRQ
View
DRQ73-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 405.6µH Inductance - Connected in Series 101.4µH Inductance - Connected in Parallel 527mOhm DC Resistance (DCR) - Parallel 730mA Nonstandard, DRQ
View
DRQ125-100-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 38.62µH Inductance - Connected in Series 9.654µH Inductance - Connected in Parallel 18.9mOhm DC Resistance (DCR) - Parallel 5.35A Nonstandard, DRQ
View
DRQ127-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 188.2µH Inductance - Connected in Series 47.05µH Inductance - Connected in Parallel 71.9mOhm DC Resistance (DCR) - Parallel 2.95A Nonstandard, DRQ
View
DRQ73-471-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 1.863mH Inductance - Connected in Series 465.8µH Inductance - Connected in Parallel 2.36Ohm DC Resistance (DCR) - Parallel 350mA Nonstandard, DRQ
View
DRQ127-100-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 41.88µH Inductance - Connected in Series 10.47µH Inductance - Connected in Parallel 17.2mOhm DC Resistance (DCR) - Parallel 6.04A Nonstandard, DRQ
View