Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 33.92µH
Inductance - Connected In Series 135.7µH
Tolerance ±20%
Current Rating - Parallel 3.23A
Current Rating - Series 1.61A
Current Saturation - Parallel 6.22A
Current Saturation - Series 3.11A
DC Resistance (DCR) - Parallel 60mOhm
DC Resistance (DCR) - Series 241mOhm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.492" L x 0.492" W (12.50mm x 12.50mm)
Height 0.315" (8.00mm)
DRQ73-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 17.69µH Inductance - Connected in Series 4.422µH Inductance - Connected in Parallel 29.7mOhm DC Resistance (DCR) - Parallel 3.09A Nonstandard, DRQ
View
DRQ73-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 405.6µH Inductance - Connected in Series 101.4µH Inductance - Connected in Parallel 527mOhm DC Resistance (DCR) - Parallel 730mA Nonstandard, DRQ
View
DRQ127-821-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 3.272mH Inductance - Connected in Series 818.1µH Inductance - Connected in Parallel 1.47Ohm DC Resistance (DCR) - Parallel 650mA Nonstandard, DRQ
View
DRQ127-8R2-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 35.44µH Inductance - Connected in Series 8.861µH Inductance - Connected in Parallel 15.7mOhm DC Resistance (DCR) - Parallel 6.32A Nonstandard, DRQ
View
DRQ127-102-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 4.02mH Inductance - Connected in Series 1.005mH Inductance - Connected in Parallel 1.66Ohm DC Resistance (DCR) - Parallel 610mA Nonstandard, DRQ
View
DRQ74-102-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 4.036mH Inductance - Connected in Series 1.009mH Inductance - Connected in Parallel 3.89Ohm DC Resistance (DCR) - Parallel 270mA Nonstandard, DRQ
View
DRQ74-151-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 600µH Inductance - Connected in Series 150µH Inductance - Connected in Parallel 591mOhm DC Resistance (DCR) - Parallel 690mA Nonstandard, DRQ
View
DRQ127-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 188.2µH Inductance - Connected in Series 47.05µH Inductance - Connected in Parallel 71.9mOhm DC Resistance (DCR) - Parallel 2.95A Nonstandard, DRQ
View
DRQ73-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 194.5µH Inductance - Connected in Series 48.62µH Inductance - Connected in Parallel 241mOhm DC Resistance (DCR) - Parallel 1.08A Nonstandard, DRQ
View
DRQ127-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 397.2µH Inductance - Connected in Series 99.31µH Inductance - Connected in Parallel 163mOhm DC Resistance (DCR) - Parallel 1.96A Nonstandard, DRQ
View
DRQ127-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 19.36µH Inductance - Connected in Series 4.841µH Inductance - Connected in Parallel 9.17mOhm DC Resistance (DCR) - Parallel 8.25A Nonstandard, DRQ
View
DRQ127-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 397.2µH Inductance - Connected in Series 99.31µH Inductance - Connected in Parallel 163mOhm DC Resistance (DCR) - Parallel 1.96A Nonstandard, DRQ
View