Categories
Inductors, Coils, Chokes / Arrays, Signal Transformers
Datasheet DRQ Series
Standard Package 1
Manufacturer Eaton - Electronics Division
Series DRQ
Packaging Cut Tape (CT)
Part Status Active
Number of Coils 2
Inductance - Connected In Parallel 101.6µH
Inductance - Connected In Series 406.4µH
Tolerance ±20%
Current Rating - Parallel 860mA
Current Rating - Series 430mA
Current Saturation - Parallel 990mA
Current Saturation - Series 490mA
DC Resistance (DCR) - Parallel 383mOhm
DC Resistance (DCR) - Series 1.53Ohm
Shielding Shielded
Ratings -
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case Nonstandard
Size / Dimension 0.299" L x 0.299" W (7.60mm x 7.60mm)
Height 0.175" (4.45mm)
DRQ74-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 132µH Inductance - Connected in Series 33.01µH Inductance - Connected in Parallel 143mOhm DC Resistance (DCR) - Parallel 1.41A Nonstandard, DRQ
View
DRQ74-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 132µH Inductance - Connected in Series 33.01µH Inductance - Connected in Parallel 143mOhm DC Resistance (DCR) - Parallel 1.41A Nonstandard, DRQ
View
DRQ127-8R2-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 35.44µH Inductance - Connected in Series 8.861µH Inductance - Connected in Parallel 15.7mOhm DC Resistance (DCR) - Parallel 6.32A Nonstandard, DRQ
View
DRQ74-470-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 198.6µH Inductance - Connected in Series 49.64µH Inductance - Connected in Parallel 216mOhm DC Resistance (DCR) - Parallel 1.15A Nonstandard, DRQ
View
DRQ127-1R0-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 3.284µH Inductance - Connected in Series 821nH Inductance - Connected in Parallel 2.61mOhm DC Resistance (DCR) - Parallel 15.5A Nonstandard, DRQ
View
DRQ73-3R3-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 14.16µH Inductance - Connected in Series 3.54µH Inductance - Connected in Parallel 25.9mOhm DC Resistance (DCR) - Parallel 3.31A Nonstandard, DRQ
View
DRQ73-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 405.6µH Inductance - Connected in Series 101.4µH Inductance - Connected in Parallel 527mOhm DC Resistance (DCR) - Parallel 730mA Nonstandard, DRQ
View
DRQ125-100-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 38.62µH Inductance - Connected in Series 9.654µH Inductance - Connected in Parallel 18.9mOhm DC Resistance (DCR) - Parallel 5.35A Nonstandard, DRQ
View
DRQ73-330-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 137.6µH Inductance - Connected in Series 34.41µH Inductance - Connected in Parallel 166mOhm DC Resistance (DCR) - Parallel 1.31A Nonstandard, DRQ
View
DRQ125-4R7-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 21.1µH Inductance - Connected in Series 5.274µH Inductance - Connected in Parallel 10.5mOhm DC Resistance (DCR) - Parallel 7.18A Nonstandard, DRQ
View
DRQ125-101-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 410.8µH Inductance - Connected in Series 102.7µH Inductance - Connected in Parallel 170mOhm DC Resistance (DCR) - Parallel 1.78A Nonstandard, DRQ
View
DRQ74-102-R
Eaton - Electronics Division, Shielded 2 Coil Inductor Array 4.036mH Inductance - Connected in Series 1.009mH Inductance - Connected in Parallel 3.89Ohm DC Resistance (DCR) - Parallel 270mA Nonstandard, DRQ
View